1. Parameter
| Working Pressure (min./max.) | 0.1 ... 14 bar |
|---|---|
| Adjustment Range (min./max.) | 0.1 ... 4.5 bar 0.1 ... 6.9 bar 0.1 ... 8.6 bar 0.1 ... 10.4 bar |
| Ambient Temperature (min./max.) | -40 ... 70 °C |
| Medium Temperature (min./max.) | -40 ... 70 °C |
| Medium | Compressed air, clean and dry |
| Nominal Flow | Qn 900 l/min |
| Port Size | 1/4 NPT, Internal thread |
| Weight | 2.3 kg |
2. Pressure vs lever travel

3. Pipe Connections
Port 1 - OUT, full inlet pressure when lever is moved 10° clockwise from “Off” (facing lever side of valve).
Port 2 - IN pressure.
Port 8 - OUT, graduated pressure when lever is moved clockwise from “Off”.
4. Models
HE-2-X CONTROLAIR Valve - The lever returns from the extreme position to the valve’s “clutch” or “Off” position when the operating force is removed.
HE-2-FX CONTROLAIR Valve - Lever remains in the position where released. Holding friction is adjustable.
HE-2-LX CONTROLAIR Valve - The lever returns to the valve’s “Neutral” or “Off” position when manually moved out of the latch position (extreme travel position).