BIH QGBQ Light Cylinder
Category:
BIHPneumatic Cylinder
Product Description
1. Parameter
| Type | QGBQ(Basic) | QGBQ-F(Valve set) | |||||||||||
| QGBQ-K(switch set) | QGBQ-FK (SV set) | ||||||||||||
| Bore in mm (Ømm) | 32 | 40 | 50 | 63 | 80 | 100 | 32 | 40 | 50 | 63 | 80 | 100 | |
| Max. Stroke (mm) | 500 | 800 | 1000 | 500 | 800 | 1000 | |||||||
| Working Pressure | 0.05--0.8MPa | 0.15--0.8MPa | |||||||||||
| Pressure-proof | 1.2MPa | ||||||||||||
| Working Speed | 50--70mm/sec | 50--500mm/sec | |||||||||||
| Working temperature | 5--60ºC | 5--50ºC | |||||||||||
| Medium | Air or dry air | ||||||||||||
| Lubrication | Unnecessary but possible | ||||||||||||
| Cushion | Cushion at both end | ||||||||||||
| Tolerance of Stroke in mm | S<=500mm | Ø32; Ø40; Ø50:0+2.0 Ø63; Ø80; Ø100:0+2.5 | |||||||||||
| S>=501mm | Ø32; Ø40; Ø50:0+2.5 Ø63; Ø80; Ø100:0+3.0 | ||||||||||||
| Cushioning Stoke (mm) | 20 | 25 | 20 | 25 | |||||||||
| Theoretical transmitting force(N)(at pressure of 0.5MPa) | Push | 392 | 608 | 960 | 1519 | 2460 | 3842 | 392 | 608 | 960 | 1519 | 2460 | 3842 |
| Pull | 333 | 510 | 774 | 1333 | 2215 | 3606 | 333 | 510 | 774 | 1333 | 2215 | 3606 | |
a. Technical Data for Switch
| Type | CK-J1A.CK-J1B | ||
| Operating Voltage | AC.DC: 24--220V | ||
| Operating Current | 10--300mA | ||
| Max. Contact Capacity | 16W | ||
| Current Leakage | 0 | ||
| Voltage-proof | 1500V | ||
| Lamp | Brighten at ON | ||
| Acting time | <=1msec | ||
| Insulation resistance | >=1.5MΩ | ||
| Available Cylinder | CK-J1: QGBQ32-50 CK-J1B: QGBQ63-100 | ||
| Operating temprature | -10--+70ºC | ||
| Ambinent relative humidity | <=90% | ||
| Available Unit | Program Controller, Relay etc. |
b. Technical Data for Valve
c. Min. stroke for cylinder
| Cylinder | Mounting | Except MT4 | For MT4 mounting |
| Switch | With Soft wire | With Soft wire | |
| Cylinder with switch (QGBQ-K) | 20mm | 125mm | |
| Cylinder with valve (QGBQ-F) | 60mm | 75mm | |
2. Cylinder type explaination
For example
The air cylinder have valve, switches,bore Ø50mm,stroke 80mm double clevis type, two DC switches, anamnestic valve,voltage DC12V, DIN link wires. Then: QGBQ-50-80MF1-FC6D-KE2
3. Symbol

4. Models
1. QGBQ-K is with switches cylinders,cylinders stroke can be adjusted easy.
2. QGBQ-F with valve cylinders save connecting time and space because of combined cylinder and valve.so install and repair quickly. There are 2 kinds: single control and double control.
Cylinders with single control have Pushing when electrify valve and plling when electrify valve.because valves can interchange so the cylinder action could interchange too.single control valve has no-memory,when turn of electricity,the valve rod return position,the cylinder change direction also.
The cylinders with Double control valve are self-holding,the valve can memory ,when turn off electricity ,the valve rod dont moving and the cylinder rod hold,so turn off electricity suddenly dont affect the cylinder.
The cylinders with valve install small and low-power solenoid first valve,winding all coverd by plastic,sealed and safety.
3. QGBQ-FK cylinders are combined by cylinder with valve and switch,that are small automation system , achieve machine and electricity intrgrative.
4. Double piston rods and backward stroke adjustable and forward stroke adjustable cylinder are coming from QGBQ, almost all accessory are same.double piston rods cylinder can output force both ends. backward stroke adjustable and forward stroke adjustable cylinder are mounted limit.so the cylinder could adjust stroke.